Flatpack Specifications |
The standard temporary building is designed to be the same configuration as an ISO container and can be transported fully erected using the same handling equipment or flat packed to reduce transport volume. The flatpack units (in transpacks of approximately 26 inch) are supplied with completely pre-fabricated floor (with PVC floor as standard) and ceiling (with all electrical installations built in such as electrical distribution, lamps and cables). During transport a steel non-slip insert is placed between each ISO corner to secure containers from sliding. The construction of the transpack is solid enough to enable transport and handling by fork lift, 4 units at a time. The modular structure is designed as a light construction consisting of floor and roof frames and corner profiles. The construction enables complexing of individual containers in longitudinal and transverse directions without limits. The container’s effective life span is ten (10) years minimum under harsh field conditions. It is capable of sustaining at least three (3) assemblies and three (3) disassemblies during its life span allowing the system to be broken down into flatpacks and relocated. |
Typical Specifications |
||||
Dimensions |
ISO Container sizes (Approx. 20 ft x 8 ft x 8.5 ft tall) or built to suit. 160 square feet inside area per unit |
|||
Weight |
Approximately 4,400 pounds |
|||
Steel Framework - Material - Fittings |
|
|||
Side panels |
|
![]() |
||
Floor - Insulation - Floor cover - Permitted loading |
Mineral wool Glued PVC floor covering with welded connections as standard 50 Lbs/Sq Ft as standard |
|||
Roof - External wainscot - Insulation - Permitted loading |
EPDM rubber with heat reflecting characteristics AC Foam III. LTTR value: 15.3 (2.5 inch panel) UL standard 263 fire resistance classification (ASTM E 119) 100 Lbs/Sq Ft as standard |
|||
Doors - External door |
Steel, single fold, filled doors. 1 door as standard |
|||
Windows |
Double Hung Windows as required are made of PVC, at least double glazed. The windows meet International Building Code (IBC) requirements. 1 window per unit is standard. |
|||
Electrical Installation - Standard - Voltage - Internal Distribution - Ceiling Lights |
iaw US Regulations 120 V / 60 hz Electrical Distribution Box Recessed |
|||
Heating / Air Conditioning |
Options available |
|||
Plumbing |
Upon Request (Toilet, shower, sink, kitchen, laundry, etc) |
|||
Mounting |
Flat hard surface (concrete, asphalt), or concrete corner blocks |
|||